ADI AMC-941 canister type load cell (sometimes called a column load cell or compression load cell) is a robust force sensor designed primarily for measuring large compressive loads. It has a cylindrical, or canister-like shape with a flat top and bottom. These cells are optimized almost exclusively for compression (pushing) forces and are known for their high capacity and stability. The load is typically applied to the center of the top surface, which compresses the internal sensing element (often a column or shear web arrangement). Strain gauges bonded inside the canister measure the resulting axial deformation. Due to the harsh industrial environments they often operate in (like under silos or bridges), they are usually hermetically sealed (welded) or highly protected to provide excellent ingress protection (IP rating) against dust and moisture.
Product Type
Single Point Aluminium Load Cell
Usage
Table top scales, Counting and postal scales, Check weighers.
Material
Aluminium
Output
Analog Sensor
Theory
Resistance Sensor
Compensated Temperature
10 To 60 Celsius (oC)
Rated capacity (Kgf)
10, 20, 30, 40, 50
Excitation Voltage
10 V DC – Maximum 15 V DC
Rated Output
2.0 mV/V
Non – Linearity
< +/- 0.025 % of FSO (Full Scale Output)
Hysteresis
< +/- 0.03 % of FSO
Non-Repeatability
< +/- 0.02 % of FSO
Creep error (30 minutes)
< +/- 0.03 % of FSO
Zero Output
+/- 1.0 % of FSO
Input Resistanc e
750 +/- 10 Ohms
Output Resistance
700 +/- 5 Ohms
Insulation Resistance
>1000 Mega Ohms
Safe Overload
150 % of Rated Capacity
Ultimate Overload
300 % of Rated Capacity200 % of Rated Capacity
Temperature
Compensated Range
0 to 60° C
Temperature Effect on
Output
< 0.0015 % FSO/° C
Temperature Effect on
Zero
< 0.0020 % FSO/° C
Side Load Allowed
50 % of Rated Capacity
Deflection
< 0.4 mm at Rated Load
Finish & Construction
Electroless Nickel Plated Tool Steel.
Stainless Steel Available optionally.
Environment Protection
IP 67
A Column Load Cell (also called a Canister or Compression Load Cell) is a cylindrical force sensor designed specifically to measure extremely high compression forces.
Column Load Cells are the standard choice for projects involving the weighing or monitoring of massive, static structures.
Given the enormous forces involved, specialized hardware is critical to ensure safety and prevent catastrophic failure or measurement error:
Column Load Cells must be specified carefully, as their failure can be extremely costly and dangerous.
For permanent installations involving hundreds of tons, durability and protection are paramount:
WhatsApp us