| Temperature Scanner |
|
|
|
|
|
Applications
|
- Large chemical, pharmaceutical, fertilizer, petrochemical, power and cement plants.
- Winding & bearing protection for large Motors and Generator Sets.
|
|
|
|
Features
|
- Excellent accuracy and repeatability.
- Dual slope integrating technique with auto zero and auto polarity.
- Automatic cold junction and line resistance compensation.
- Minimum effects of temperature, humidity and power flactuations.
- Real Time Clock with RS232C or Centronics compatible printer port available optionally.
- Microprocessor based system with key board operation.
- Data storage in non-volatile RAM.
- Various relay output combinations available.
- Signal selection through solid state multiplexers.
|
|
|
|
|
|
Specifications
|
|
MODEL
|
A - DTS - 3508 |
B - DTSC - 3508 |
|
|
INDICATION
|
Data indicated by 3 1/2 digits and channel number indicated by 2 digits : 7 segment LED display of 12.5mm character height with auto polarity indication.
|
|
|
NUMBER OF CHANNELS
|
4 TO 32 Channels available. (No. of channels is in multiple of 4).
|
|
| OPEN SENSOR INDICATION |
Indicated by Data Field as "OPEN".
|
|
|
SCAN RATE
|
Adjustable by keyboard switches provided on front panel. Setting range from 1 to 30 secs.
|
|
|
SCANNING MEDIUM
|
Solid state multiplexers.
|
|
|
TYPE OF CONTROL
|
|
ON/OFF Type.
|
|
|
NUMBER OF CONTROL POINTS PER CHANNEL
|
|
1 OR 2. |
|
|
CONTROL SETTING
|
|
Control setting adjustable over full span by Front Panel Keyboard switches. |
|
|
PROGRAMME MEMORY RETENTION
|
Programme stored in RAM is protected by battery back-up ( Battery is charged when power is ON ).
|
|
|
CONTROL OUTPUT
|
|
1 SPDT contact per relay for 3A resistive load for 230V, 50Hz supply. |
|
|
RELAY ON STATUS
|
|
Indicated by front panel LEDs. |
|
|
CONTROL ACTION / OPEN SENSOR PROTECTION
|
Relay energises or de-energises when set Temp. is reached / when sensor is open, relay can be energised or de-energised ( to be specified ).
|
|
|
POWER REQUIREMENT
|
110V or 230V, 50Hz / 15VA.
|
110V or 230V, 50Hz / 20VA. |
|
|
ENCLOSURE
|
92 (W) x 186 (H) x 280 (D) / 186 (W) x 186 (H) x 330 (D).
|
|
|
OPTIONS
|
Non Microprocessor based Scanners with scan rate setting by pot. meter are available in 6/8/12 or 16 channels in 186 (W) x 92 (H) x280 (D) with ranges as specified in TABLE below.
Options: 1). Real Time Clock with Battery Backup. 2). RS232C Serial Port or Centronix compatible paraller printer port. |
|
|
|
|
INPUT CALIBRATION & RANGE TABLE
|
|
|
|
INPUT
|
TYPE
|
RANGE °C
|
RESO °C
|
ACCURACY
|
|
|
Fe/Co T/C
|
J
|
0-700
|
1 |
±0.1%±1 |
|
|
Cr/Al T/C
|
K |
0-1200
|
1 |
±0.1%±1 |
|
| Cu/Co T/C |
T |
0-200
|
0.1 |
±0.1%±2 |
|
|
|
| PTPTRH 10% |
S |
0-1700
|
1 |
±0.1%±2 |
|
| PTPTRH 13% |
R |
0-1700
|
1 |
±0.1%±2 |
|
| RTD |
PT-100 |
-100 to +200
|
0.1 |
±0.1%±2 |
|
|
|
|
|
|
|
| |
|
|
|
|