| Temperature Controller |
|
|
|
|
|
Applications
|
- Process Industries.
- Laboratories.
- Heat Treatment Plants.
- Plastic Industries.
|
|
|
|
Features
|
- Bright digital display for easy viewing.
- Excellent accuracy and repeatability.
- Dual slope integrating technique with auto zero and auto polarity.
- Automatic cold junction and line resistance compensation.
- Minimum effects on performance against temperature, humidity and power flactuations.
- Digitally linearised scale available optionally.
- Control setting by push to set method to avoid any error.
- ON/OFF or proportional control available with multiple relay / control output.
- S.S.R. output provided optionally for trouble free reliable operation.
|
|
|
|
|
|
Specifications
|
|
MODEL
|
TC - 4010/11 TC - 4020/21
|
DTIC - 3510/3511 DTIC - 3520/3521
|
|
|
INDICATION/DISPLAY
|
Calibrated Dial
|
3 1/2 Digit - 7 Segment RED LED display of 12.5mm character height with auto polarity indication.
|
|
|
INPUT RESISTANCE/EXCITATION CURRENT
|
Greater than 100kΩ for Thermocouple input/ 1mA excitation current for RTD input.
|
|
|
SENSOR BREAK INDICATION |
--
|
Three least significant digits Blank and most significant didit On.
|
|
|
COLD JUNCTION & LINE RESISTANCE COMPENSATION
|
Automatic cold junction compensation over ambient temperature of 0 to 60°C. Upto 500Ω line
resistance for Thermocouple and up to 20Ω line resistance for RTD three wire configuration.
|
|
|
NO. OF CONTROL POINTS
|
ONE OR TWO.
|
|
|
TYPE OF CONTROL
|
ON / OFF Type or Time Proportional Type.
|
|
|
SETTING METHOD
|
Potentiometric.
|
|
|
SETTING ACCURACY
|
±2% of span.
|
No setting error by push to set type facility.
|
|
| CONTROL OUTPUT |
1 Change Over Relay contact, 3Amp. Resistive Load Capacity at 230V AC.
|
|
|
RELAY STATUS
|
Indicated by RED LED.
|
|
|
OPEN SENSOR PROTECTION
|
Up scale with Relay Trip.
|
|
|
OPERATING AMBIENT RANGE
|
0 to 60°C Temperature & 95% R.H. at 40°C (non - condensing).
|
|
| EFFECT OF TEMPERATURE ON ZERO AND SPAN
|
For - DTIC - ±0.05 digit/ °C on zero & ±0.01% of Span/°C on span.
For - TC - ±0.5%/° on zero & ±0.2% of span/°C on span.
|
|
|
POWER REQUIREMENT
|
230V ± 10%, 50HZ. 5VA power consumption.
|
|
|
INPUT/OUTPUT TERMINATION
|
Barrier terminal strip for 0.5 - 1.2mm wire connection.
|
|
|
ENCLOSURE
|
92x92 (mm) panel cutout with 150mm depth.
|
92x92 (mm) / 186x92 (mm) panel cutout with 150mm depth.
|
|
|
|
ON/OFF type - with 0.1% dead band around set point.
Time Proportional type - with
1. Proportional band of 20% adjustable.
2. Reset for adjustment of offset.
3. Proportional period of 10 second fixed.
Code : 3rd digit : 0-ON/OFF, 1-Proportional. 4th digit indicates No. of set points.
Temp. controllers in flameproof enclosures are also available. |
|
|
|
|
INPUT CALIBRATION & RANGE TABLE
|
|
|
|
INPUT
|
TYPE
|
RANGE °C
|
RESO °C
|
|
Standard %±digit |
Linearised (L) %±digit |
|
|
|
Fe/Co T/C
|
J
|
0-400*
|
1 |
±0.5%±1 |
±0.1%±1 |
|
|
|
|
Cr/Al T/C
|
K |
0-400*
|
1 |
±0.5%±1 |
±0.1%±1 |
|
| |
|
0-1000
|
1 |
±-0.5%±1 |
±0.1%±1 |
|
|
|
| Cu/Co T/C |
T |
0-200
|
0.1 |
- |
±0.1%±2 |
|
|
|
| PTPTRH 10% |
S |
0-1700
|
1 |
- |
±0.1%±2 |
|
| PTPTRH 13% |
R |
0-1400*
|
1 |
- |
±0.1%±2 |
|
|
|
| RTD |
PT-100 |
-100 to +200
|
0.1 |
±0.5%±1 |
±0.1%±1 |
|
| |
|
-100 to +600
|
1 |
±0.2%±1 |
±0.1%±1 |
|
|
|
|
|
| |
|
|
|
|